HSE Guide P35 – Printing with UV-Curable Inks (Ozone)

A Guide produced by HSE in 2005 which describes good practice for printing using UV-curable inks. It discusses (briefly) that LEV should be used to remove any ozone produced by the process. Guide P35 pdf

HSE Guide – HSG 258 – Controlling Airborne Contaminants at Work – A Guide to Local Exhaust Ventilation (LEV)

Second Edition, Published by HSE 2011 This is HSE’s current guide on LEV and related topics.  Here you will find recommended Duct Velocities, Captor Velocities, Face Velocities, and other design criteria. The various types of hoods, filters, fans and discharges …

Where Can I Source LEV Labels?

Have you ever required small run batches of specific LEV related labels? OXYL8 Ltd can now offer both standard and bespoke labels through their subsidiary website LEVShop – Labels (bespoke labels can include Logo, tel number, website etc) at a …

Video – “What Happens When a Centrifugal Fan Runs in Reverse”?

Latest OXYL8 LEV training video on YouTube which shows what happens when a Centrifugal fan is incorrectly wired (ie phases the wrong way round) – a situation which is all too common (estimated that approx 7% are incorrectly wired). The …

Emission and Exposure Control-Related Ventilation Regulations – USA

This neat summary document, produced in 2015 by the well-respected Industrial Ventilation specialist Dr Jeff Burton summarises the USA standards and requirements for Ventilation systems used to control personal exposures. A copy of this short document can be downloaded here:- 10-USA …

CoSHH Essentials – Easy Steps to Control Chemicals

HSE Guide (looks like published Sept 2009) dealing with the foundations and “Technical Basis for the CoSHH Essentials: Easy Steps to Control Chemicals”. If you are familiar with Benchmarking (as per HSG258) then this document will provide you with so …

Video – “How to Use the PITOT Tube”

New OXYL8 training video on YouTube which provides an excellent introduction to the PITOT Tube, how to make the connections to a Manometer and how to take correct readings in a duct How to Use the PITOT Tube

HSE Guidance: “HSG276 – Isocyanate Paint Spraying – Safely Managing Spray Booths and Rooms

This HSE Guidance is aimed at vehicle body shop owners, managers and supervisors, their employees (particularly paint sprayers) and suppliers. It will also be useful to industries, other than motor vehicle repiair (MVR), where there is spraying of Isocyanate-containing paints …

SHAPA Dust Extraction – Five Ways to Achieve Long Life with Minimal Expense.

SHAPA = Solids Handling & Processing Association Visit www.shapa.co.uk to find out more about membership. This document is titled Dust Extraction – five ways to achieve long life with minimal expense.  It is a good document on how to get …

ACGIH Industrial Ventilation: A Manual of Recommended Practice for Operation and Maintenance

A useful manual which is intended as a companion to the 31st Edition and future editions of Industrial Ventilation: A Manual of Recommended Practice for Design. Some of the highlights of this manual include: Guidance and training information for personnel …